Shortlist the Presidium PRIM II only if your gem work already has a visual microscopy lane and you want a separate dry reflectivity reading for transparent, flat-polished facets. This is a companion instrument, not another gem microscope. Keep your existing microscope for inclusion views, surface features, and photographs; keep an existing RI tool if it already answers your question. The PRIM II is a narrow fit for an owner who can place a transparent facet of at least 3 mm over the test opening.[2] The maker describes testing transparent gemstones with flat polished surfaces, while the chart warns against opaque stones and requires a flat surface.[1][3]
That boundary matters more than the broad product title. Skip it for rough pieces, opaque material, or stones without an accessible flat facet. Also skip it if you expect universal identification, appraisal, authenticity decisions, or a reliable instant classification. Its useful question is narrower: does a dry, instrument-generated RI estimate add a second check beside what you can see through the microscope?
As an Amazon Associate I earn from qualifying purchases.
Check the exact PRIM II offer on Amazon

What it actually measures
The mechanism is worth stating plainly. The handbook says the PRIM II detects the quantity of light—intensity—reflected from the surface of a cut and polished gemstone. That intensity is fed into a microcontroller, which performs a calculation and converts it into the displayed refractive-index reading.[2] This is a numerical reading calculated from reflected light, rather than an enlarged image. It can sit beside visual examination, not replace it.
The documented reading span is 1.000 to approximately 3.000.[1][2] Treat that as coverage, not an accuracy score or a ranking against other testers. The separate reference chart prints tolerance levels in brackets for readings derived from the product.[3] Those tolerances are not one guaranteed ± accuracy. The handbook’s overlapping examples are a useful brake on overconfidence: synthetic spinel/synthetic sapphire and high zircon/GGG can have overlapping reflectivity index results.[2] A reading can narrow a question without proving what the stone is.
How it fits a real bench
For the right owner, the workflow is separate from wet refractometry: place the eligible facet on the test pad, use the blackout cover as instructed, and read the display. The maker emphasizes no messy RI liquids.[1] A practical bench setup is: work around 18–27°C, keep the pad and stone clean and dry, and pay attention to the low-battery indicator. Those conditions matter when deciding whether the meter suits your routine.[2]
Do not turn this into a scratch-test, DIY hardness, specific-gravity, or self-calibration project. The handbook explicitly says self-calibration should not be attempted.[2] The manufacturer says units are factory-calibrated and directs users to its service center when recalibration is needed. That is its documented policy, not our inspection of a shipped unit.[2]
The standalone RI reading does not need a PC. The maker separately offers downloadable Windows and Mac software routes.[1] The linked handbook says the software is not yet compatible with Mac, while the current product page exposes both Windows and Mac download links.[1][2] Those documents do not agree; download availability alone does not prove compatibility with your present operating system or the features you need. Confirm those details if the database is important to your purchase. The optional software is a database workflow that uses known inputs such as color, hardness, and S.G.; those are entered properties, not measurements made by this tester.[1]
Package and power checks
The handbook’s package list is specific: the meter, protective carrying case, quick guide, refractive-index reference list, USB cable, and QR-code card.[2] It does not establish included stones, a calibrant, an AC brick, or a software CD. The maker lists one 9V battery and an optional recommended Presidium USB AC adapter, with the adapter not included.[1] Confirm the battery and current bundle at checkout rather than assuming the product page, an older manual, and a supplier photograph describe the same shipment. The illustrated stones in the product image are not an inclusion promise.
Check that the linked offer identifies the Refractive Index Meter II, rather than another Presidium tester.[4] The sensible purchase gate is fit first: transparent material, flat facet at least 3 mm, a microscope already available for visual work, and a reason to want a separate dry RI estimate.
Verdict
Buy the PRIM II as a specialized companion when your microscope handles visual microscopy and you routinely have suitable transparent, flat-polished facets of at least 3 mm. It can add a dry reflected-light RI estimate across the documented 1.000–3.000 range, but it cannot replace visual examination or establish identity, authenticity, treatment, origin, valuation, or certification. Skip it for rough, opaque, or inaccessible-facet material, or when your existing RI tool is already adequate.
As an Amazon Associate I earn from qualifying purchases.
Check the exact PRIM II offer on Amazon